BFAM HV Shunt Capacitor

Application: for enhancement of power factor, lowering circuit loss and improve voltage quality of rated voltage 1kV and above power distribution system. Standards: IEC 60871-1 Parameters:    Rated voltage: 1-21kV. Rated capacity: 150-500kVar. Features:          1.Compact design and light in weight. 2.Low loss and temperature-rise. 3.Long operation endurance. 4.Low partial discharge performances.

TAL

Application: for absorbing harmonic current generated by the harmonic source and restraining  harmonics in 6-35kV power system. Parameters:  Rated voltage: 6-35kV. Rated capacity: 0.3-60Mvar. Features:       1.Compact design and reliable operation. 2.Low loss. 3.Low operating temperature. 4.Flexible structure and easy for operation.

TBB

Application: for enhancement of power factor, lowering circuit loss and improve voltage quality  in rated voltage 1-110kV.  power distribution system. Standards: IEC 60871-1 Parameters:   Rated voltage: 1-110kV. Rated capacity: 0.3-60Mvar. Feature:           1.Compact design and reliable operation. 2.Inside- capacitors fuse for failure protection. 3.Outside capacitors with discharge circuit for over voltage relay                            protection. 4.With no- load tapping changer for capacity of the capacitor. 。

TBBFX

Application: for enhancement of power factor, lowering circuit loss and improve voltage quality of rated voltage 1-10kV. power distribution system. Standards: IEC 60871-1 Parameters:    Rated voltage: 1-10kV. Rated capacity: 0.3-20Mvar. Features:         1.Automatic control of reactive power. 2.Compact design. 3.High utilization of the capacitor. 4.Complete protection and control protection and high automation level.

TBBS

TBBS substation type auto-switched high-voltage shunt capacitor installation is usually installed besides 10kV or 6kV system of the substation. The equipment can effectively increase the power factor, reduce circuit losses, improve voltage quality and compensate reactive power. The equipment is divided to several capacitor banks, according to the load of system, with auto-switching of SF6 switch & controlling of micro-controller, we can realize auto compensating of the reactive power. Meanwhile, some protection, such as open-delta unbalance voltage, single capacitor error, short circuit, over current, over voltage, under voltage etc, are set up to make system stable and reliable.

TBBX

Application: for enhancement of power factor, lowering circuit loss and improve voltage quality in rated voltage 6.6-12kV.power distribution system  and start-up operation of the motors. Standards:     IEC 60871-1 Parameters:  Rated voltage: 6-10kV. Rated capacity: 50-1500kVar. Features:       Compact design and cost-effective.

TBBZ

Application: for enhancement of power factor, lowering circuit loss and improve voltage quality in 6.6kV/12kV power distribution system. Standards: IEC 60871-1 Parameters:    Rated voltage: 6-10kV. Rated capacity: 100-1200kVar. Feature:           1.Perfect protection function. 2.Compact design and reliable operation. 3.Advanced control mode. provide for control power transformer itself. 4.Convenient for installation, easy maintenance.