Showing all 15 results

Show sidebar

Cut-out Fuse

Application: protection device for protecting power system from overload and short-circuit failure. Standards: IEC60282-2:2008, ANSI Parameters: 12kV~36kV Features: Excellent over-current protection High power frequency withstand voltage Reliable insulation capability.

FLN36

Application: for making and breaking of load current, over-load current and short-circuit current to control and protect the circuit and transformer, etc. in power distribution system. Standards: IEC 60265-1, IEC 62271-105. Features:   1.Indication of the active contact to show the operation status of the switch. 2.High insulation level. 3.Fully sealed and reliable operation.

FZN21

Application: for making and breaking of load current, over-load current and short-circuit current to control and protect the circuit and transformer, etc. in power distribution  system. Standards: IEC 60265-1, IEC 62271-105. Features:   1.High breaking capacity. 2.Compact design and light in weight. 3.Reliable operation and long operation endurance

JN15

Application: in 12, 24kV power system for HV busbars. Standards: IEC 62271-102 Parameters:  1.Rated voltage: 12, 24kV. 2.Rated short-time withstand current: 31.5-40kA.

NFW1

Application: for making and breaking load current and short-circuit breaking current in 12kV AC50Hz power system. Standards: IEC 60265-1 Features:  1.High breaking capacity. 2.Safe and reliable operation. 3.Maintenance-free. 4.Flexible installation. 5.With automation distribution interfac

NFZ77

Application: for making and breaking rated current and overload current, protecting the equipments from phase-loss fault in 35kV AC50Hz power system. Standards: IEC 60265-1, IEC 62271-105. Features:   1.Compact design and light in weight. 2.High breaking capacity. 3.Maintenance-free. 4.Safety and reliable operation. 5.Long mechanical life.

NV1 Series (17.5kV,24kV), Indoor Type

Ratings: Rated voltage 17.5kV~24kV, Rated current 630A~3150A, AC50HZ Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100

NV2 Series (12kV), Indoor Type

Ratings: Rated voltage 12kV, Rated current 630A~4000A, AC50HZ Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network. Standard: IEC62271-100

NVW2-12Y1250-25 (12kV), Outdoor Type

Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100 Parameters:   Rated voltage: 12kV. Rated current: 630-1250A. Rated short-circuit breaking current: 20kA,25kA. Features:         1.Compact design and light in weight. 2.Enclosed construction can realize anti-dust and anti-moisture. 3.Maintenance-free. 4.Both manual and electric power operation and remote control.

NVW5 (12kV), Outdoor Type

Application: for making and breaking load current, overload current and short-circuit current in 12kV AC50Hz power system, protecting and controlling of substation and equipments. Standards: IEC 62271-100 Parameters:    Rated voltage: 12kV. Rated current: 630A. Rated short-circuit breaking current: 20kA. Features:         1.Compact design and light in weight. 2.Enclosed construction filled with SF6 gas can realize anti-dust and anti-moisture. 3.Maintenance-free

ZN63A-12(VS1) (12kV), Indoor Type

Application: in 12kV power distribution system for control and protection. Standards: IEC 62271-100 Parameters:   Rated voltage: 12kV. Rated current: 630-5000A. Rated short-circuit breaking current: 20-50kA. Features:         1.Advanced arc-extinguishing mode adopted. 2.High insulation level and peak withstand current capacity. 3.Impact and vibration reduced, Less maintenance. 4.Mechanical endurance up to 20,000 times.

ZN85-40.5 (40.5kV), Indoor Type

Application: in 40.5kV power distribution system for control and protection. Standards: IEC 62271-100 Parameters:    Rated voltage: 40.5kV. Rated current: 630-2000A. Rated short-circuit breaking current: 20-31.5kA. Features:         1.High insulation level and breaking capacity. 2.Compact and modular deign. 3.Less maintenance. 4.High operation endurance. 5.Applicable to various working conditions

ZW32-12 (12kV),Outdoor Type

Ratings: voltage up to 10kV, current 630A, AC50Hz. Application: for making & breaking load current, overload current and short-circuit protection of electric systems and equipments. Standard: IEC62271-100

ZW7-40.5 (40.5kV), Outdoor Type

Application: in 40.5kV power system, for making and breaking load current, overload current and short circuit protection. Standards: IEC 62271-100 Parameters:   Rated voltage: 40.5kV. Rated current: 1250~2000A. Rated short-circuit breaking current: 20kA, 25kA, 31.5kA. Features:         1.Simple construction and easy installation. 2.High insulation level and waterproof. 3.Both spring and magnetic operation mechanism available. 4.Internal current transformers can realize multiple transformation ratio output, high secondary output.

ZW8-12(Z) (12kV), Outdoor Type

Application: in 12kV power distribution system for control and protection. Standards: IEC 62271-100 Parameters:    Rated voltage: 12kV. Rated current: 630-1000A. Rated short-circuit breaking current: 12.5-20kA. Features:          1.Low loss for the control unit. 2.Anti-dust and anti-moisture. 3.Back-up battery could be installed to ensure the normal work of 12 hours after break. 4.The programmable interface and software could facilitate the utilization. 5.Various telecommunication modes are available. 6.Remotely controlled through DMS system telecommunication