Showing 1–30 of 178 results

Show sidebar

BKMJ Dry Type Low-voltage Shunt Capacitor

BKMJ dry type low-voltage shunt capacitor is applied in nominal voltage 1000V and below power frequency AC power system for the purpose of raising the power factor, reducing the line loss and improving the voltage quality. Filled with dry type flame retardant material; it is safe and reliable with small product size and convenient installation. Executed standard: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014. CATALOG BKMJ Catalog

BZMJ Self-healing Shunt Capacitor

1.1 Electric ratings: ≤AC1000V; 1.2 Application: For improvement of power factor and power quality; 1.3 Standards: IEC/EN 60831-1:2014 IEC/EN 60831-2:2014. CATALOG BZMJ Catalog PDF

CJ19 Contactor for Capacitor Switching

1.1 Electric ratings: AC50/60Hz, up to 690V; 1.2 Standard: IEC/EN 60947-4-1 CATALOG CJ19 Contactor for Capacitor Switching PDF

DDSU666 Single Phase DIN-Rail Meter

Reliable Choice ◎ LCD Display ◎ Bi-Direction Measurement ◎ DIN-Rail installation CATALOG DDSU666 PDF

DTSU666 Three Phase DIN-Rail Meter

Reliable Choice ◎ LCD Display ◎ Bi-Direction Measurement ◎ DIN-Rail installation CATALOG DTSU666 PDF

DZ158 Moulded Case Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG DZ158 Moulded Case Circuit Breaker(DC type)

DZ158LE Residual Current Operated Circuit Breaker

1.1 Function Personnel and fire protection Cable and line protection against overload and short-circuits. 1.2 Selection I∆n ≤ 30 mA: additional protection in the case of direct contact. I∆n ≤300 mA: preventative fire protection in the case of ground fault currents. AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. 1.3 Approvals and certificates CATALOG DZ158LE Residual Current Operated Circuit Breaker PDF

eB Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrushcurrent. D curve(10-20In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG eB Miniature Circuit Breaker PDF

HDLRT0 Fuse for Distribution

HDLRT0 Fuse for Distribution 1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A; 2.Application: for protection of power distribution apparatus against over-load and short circuit; 3.Standard: IEC 60269.

HH15-QA Switch Disconnector

1.1 Application Mainly used in the distributing and motor circuit which has high short-circuit current,and acted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class with drawable low voltage complete equipment. They provide safety isolation and protection against overcurrent for any low voltage electrical circuit. 1.2 Standard: IEC/EN 60947-3. 1.3 General characteristic Full-enclosed structure Unique rolling insert type contact system.

HH15-QP Switch Disconnector

1.1 Application Mainly used in the distributing and motor circui which has high short-circuit current,and acted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class  with drawable low voltage complete equipment. They provide safety isolation and protection against overcurrent for any low voltage electrical circuit. 1.2 Standard: IEC/EN 60947-3. 1.3 General characteristic Full-enclosed structure Unique rolling insert type contact system.

HH15/QSA Fuse-switch Disconnector

1.1 Application Mainly used in the distributing and motor circu which has high short-circuit current, andacted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class with drawable low voltage complete equipment. They provide safety isolation  and protection against overcurrent for any low voltage electrical circuit. 1.2 Standard: IEC/EN 60947-3. 1.3 General characteristic Full-enclosed structure Unique rolling insert type contact system.

JCUK Connection Terminal

JCUK Connection Terminal 1. Electric ratings: Voltgae up to 690V; 2. Rated cross section area of conductor: 150mm2. 3. Standard: IEC60947-7-1

JD-5 Integrated Protector

JD-5  Integrated Protector (hereinafter referred to as protector) is applicable for overload and phase-failure protection of AC motor @ A.C.50Hz, less than AC690V rated insulation voltage and 0.5A~400A rated operating current for its continuous working or discontinuous working. Protector and AC contactor are generally used cooperatively. This product meets the requirements of IEC 60947- 4-1.

JD-5A Integrated Motor Protector

JD-5A Integrated Motor Protector (hereinafter referred to as protector) is applicable for overload, phase-failure and three-phase current unbalance protection of AC motor @ A.C.50Hz, less than AC690V rated insulation voltage and 1A~400A rated operating current for its continuous working or discontinuous working. Protector and AC contactor are generally used cooperatively. This product meets the requirements of IEC 60947-4-1.

JD-5E Integrated Motor Protector

JD-5E Integrated Motor Protector is applicable to overload and phase failure protection of AC motor working for a long time or discontinuously with AC 50Hz, rated insulation voltage AC690V and rated working current 1A-400A. The protector is usually matched with the AC contactor for use. It conforms to IEC 60947-4-1 standards.

JD-8 Integrated Motor Protector

JD-8 Integrated Motor Protector is mainly applicable to fault protection of overload and phase failure of low-voltage three-phase AC asynchronous motor in electric power system with AC frequency 50Hz and rated insulation voltage less than 690V. The protector is usually matched with the contactor in AC motor loop circuit for use. It conforms to IEC 60947-4-1 standards.

JKF8 Intelligent Low-Voltage Reactive Power Compensation Controller

JKF8 Intelligent Low-Voltage Reactive Power Compensation Controller (hereinafter referred to as 'controller' ) is a dedicated controller which can make compensations for the reactive power of low voltage distribution system. CATALOG JKF8 Catalog

JQX-10F Miniature Power Relay

1. 10A switching current 2. Various sockets available 3. Wide range of coil ratings 4. Certificate: UL, CE

JQX-13F Miniature High-Power Electromagnetic Relay

Contact switching capability of 10A; a complete range of AC/DC specifications; enclosed in transparent dust cover, a variety of mounting types; various sockets available; Specifications with state indicators available; Certifictaion: CE UL; models of the same type: LY2(N), HH62P(-L).

JSS48A Time Delay Relay

JSS48A Time Delay Relay is applicable for controlling circuit @ A.C.50Hz/60Hz, up to 380V rated control supply voltage and up to D.C. 240V rated control supply voltage as delay element to make/break circuit according to preset value.

JSZ3 Time Delay Relay

JSZ3 Time Delay Relay is applicable for automatic control system, such as machine automatic control, and complete equipment automatic control, etc.

JSZ6 Time Delay Relay

JSZ6 Time Delay Relay is applicable for automatic control system, such as machine tool automatic control, complete equipment automatic control. Etc.