NM1 Moulded Case Circuit Breaker

1.1 Certificates: KEMA, UKrSEPRO, EAC, RCC, EK; 1.2 Electric ratings: AC 690V,50/60HZ, 10~1250A; 1.3 Mounting mode: Vertical and horizontal; 1.4 Standard: IEC/EN60947-2.

NM1B Moulded Case Circuit Breaker

NM1B series moulded case circuit breaker has a rated insulation voltage of 800V, suitable for AC 50Hz, rated operating voltage of 415V (3P), 230V / 240V (1P), and rated operating current from 10A to 125A in the distribution network circuit. It is used to distribute electrical energy and protect lines and the power supply equipment from damages such as overload and short circuit. This circuit breaker has the characteristics of small size and short flashover, and is an ideal product for users. The circuit breaker is installed vertically, and it can also be installed horizontally. The product has isolation function. Standard: IEC 60947-2。

NM8(S)L ELCB

NM8(S)L earth leakage circuit breaker is mainly suitable for circuits of AC 50Hz, with the rated voltage up to 400V, and the rated current to 630A. Its main function is to provide indirect contact protection for deadly personal electric shock. Meanwhile, it can also be used to prevent electrical fires caused by earth fault current. Besides, it protects lines from overload, short-circuit, under voltage, and for infrequent conversions

NM8(S)Moulded Case Circuit Breaker

1.1 Certificates: CE, DNV, KEMA, UKrSEPRO, EAC, RCC; 1.2 Electric ratings: AC50/60Hz, AC220V~690  16A~1600A; 1.3 Standard: IEC/EN 60947-2.

NM8N moulded case circuit breaker

1.General NM8N series moulded case circuit breaker is suitable for the circuit of AC50/60Hz, with rated voltage AC690V and below, DC system rated voltage DC1000V and below, and rated current of 16A and 1600A. It can protect circuits and electric equipment against overload, short circuit or undervoltage, and can also provide protection of overload, short circuit and under voltage for infrequent start of motor. Products have functions of power distribution protection, motor protection, residual current protection and isolation. The circuit breaker can be installed vertically, installed horizontally and can also enter the line from the bottom. Standards compliant: IEC 60947-1 general rules for low-voltage switchgear and control equipment; IEC 60947-2 low-voltage switchgear and control equipment circuit breakers; IEC 60947-3 low-voltage switchgear and control equipment switches, disconnectors and fuse combination appliances; IEC 60947-4-1 Electromechanical contactors and motor starters (including motor protectors) for low voltage switchgear and control equipment.   2.Operating conditions 2.1 Temperature: Operating and storage temperature is -40° C~+70° C; the average value within 24 hours does not exceed +35° C; when the ambient temperature is -40° C~+70° C, users need to consider derating or temperature compensation whose details can be referred to in Page 2.2 Altitude: ≤ 2000m; 2.3 Pollution grade: Grade 3; 2.4 IP grade: IP40 2.5 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40 ℃ , higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20 ℃ , special measures should be taken to occurrence of dews.

NXHM Series Disconnector Switch

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for  the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A,  800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXM Series Moulded Case Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type CATALOG NXM SERIES catalog

NXMLE Series Residual Current Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type

NXMS Series Moulded Case Circuit Breaker

The moulded case circuit breaker will provide protection for the circuit and equipment in case of overload, short circuit and under voltage condition occurred in the power distribution circuit. Besides, it can also provide protection of overload, short circuit and under voltage for  the non-frequent start of motor ▪ Frame size: NXM series moulded case circuit breaker: 63A, 125A, 160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A NXMS series electronic breaker: 160A, 250A,  400A, 630A, 1000A, 1250A, 1600A ▪ Rated operational voltage: Ue (VAC): 220/230/240, 380/400/415, 690 ▪ Breaking capacity code: E, S, F, H ▪ Number of poles: 2P, 3P, 4P ▪ Release type:thermal magnetic fixed type; magnetic fixed type; electronic type. ▪ Installation method: Fixed type; plug-in type