ZW32-12 (12kV),Outdoor Type
Ratings: voltage up to 10kV, current 630A, AC50Hz.
Application: for making & breaking load current, overload current and short-circuit protection of electric systems and equipments.
Standard: IEC62271-100
SKU: ZW3212
Categories: Electrical Products, MV Apparatus, MV Circuit Breaker, Power T&D
Tags: MV Apparatus, MV Circuit Breaker, Power T&D
Related products
NXB-125 Moulded Case Circuit Breaker
Rated current: 63A, 80A, 100A, 125A;
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125 Moulded Case Circuit Breaker PDF
DZ158LE Residual Current Operated Circuit Breaker
1.1 Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.
1.2 Selection
I∆n ≤ 30 mA: additional protection in the case of direct contact.
I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
1.3 Approvals and certificates
CATALOG
DZ158LE Residual Current Operated Circuit Breaker PDF
NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection (Magnetic)
1.1 Function
Personnel and fire protection: Cable and line protection against overload and short-circuits.
1.2 Selection
Rated residual operating current
I∆n =30 mA: additional protection in the case of direct contact.
Tripping class
A and AC class
A class tripping is ensured for sinusoidal, alternating residual
currents as well as for pulsed DC residual currents, whether they be quickly or slowly increase.
AC class tripping is ensured for sinusoidal, alternating residual currents, whether they be quickly or slowly increase.
Tripping curve
B curve (3 In-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5 In-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
CE/CB/KEMA
1.4 Add-on devices
XF9 auxiliary contacts
S9 shunt release
V9 under voltage release
OVT-1 over voltage release
CATALOG
NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection PDF
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
CATALOG
NB1-63DC DC Miniature Circuit Breaker PDF