LW8A-40.5 SF6 Circuit Breaker
Application: For control and protection of 40.5kV power system.
Standards: IEC 62271-100
Parameters: Rated voltage: 40.5kV.
Rated current: 2000A.
Rated short-circuit breaking current: 31.5kA.
Features: 1.With current transformer for measurement and protection.
2.High breaking capacity by adoption of self-expansion arc-quenching theory.
3.Secure and reliable operation and high insulation level.
4.Applicable for frequent operation; easy or free of maintenance.
5.Fully sealed.
6.Easy installation and adjustment, low noise.
SKU: LW8A40
Categories: Electrical Products, HV Air-insulated Switchgear, HV Circuit Breaker, Power T&D
Tags: HV Air-insulated Switchgear, HV Circuit Breaker, Power T&D
Related products
NXB-40 Miniature Circuit Breaker
Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A;
Rated voltage: 240V;
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P+N;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity(Icu): 4500A;
Short-circuit breaking capacity(Ics): 4500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-40 Miniature Circuit Breaker PDF
NB1-63 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
NXB-63 Miniature Circuit Breaker
Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A.
CATALOGUE: NXB-63 Miniature circuit breaker PDF
NBH8 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),
short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
CATALOG
NBH8 Miniature Circuit Breaker PDF
DZ158LE Residual Current Operated Circuit Breaker
1.1 Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.
1.2 Selection
I∆n ≤ 30 mA: additional protection in the case of direct contact.
I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
1.3 Approvals and certificates
CATALOG
DZ158LE Residual Current Operated Circuit Breaker PDF
NXB-125 Moulded Case Circuit Breaker
Rated current: 63A, 80A, 100A, 125A;
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125 Moulded Case Circuit Breaker PDF