LW8A-40.5 SF6 Circuit Breaker
Application: For control and protection of 40.5kV power system.
Standards: IEC 62271-100
Parameters: Rated voltage: 40.5kV.
Rated current: 2000A.
Rated short-circuit breaking current: 31.5kA.
Features: 1.With current transformer for measurement and protection.
2.High breaking capacity by adoption of self-expansion arc-quenching theory.
3.Secure and reliable operation and high insulation level.
4.Applicable for frequent operation; easy or free of maintenance.
5.Fully sealed.
6.Easy installation and adjustment, low noise.
SKU: LW8A40
Categories: Electrical Products, HV Air-insulated Switchgear, HV Circuit Breaker, Power T&D
Tags: HV Air-insulated Switchgear, HV Circuit Breaker, Power T&D
Related products
NB1-63G Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currentsprotection of circuits against overload currents,switch,isolation,
NB1-63G circuit-breakers are used in domestic installation,as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point consideredshort-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,
Network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrus current.
CATALOG
NB1-63G Miniature Circuit Breaker PDF
eB Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT
systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-20In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
eB Miniature Circuit Breaker PDF
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection
1.1 Selection
Rated residual operating current
I∆n = 30 mA: additional protection in the case of direct contact.
Tripping class
AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big
length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.2 Approvals and certificates
CATALOG
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection PDF
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
CATALOG
NB1-63DC DC Miniature Circuit Breaker PDF
NB1-63 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
NB3LE Residual Current Operated Circuit Breaker with Over-current Protection
Rated residual operating current
I∆n = 30 mA: additional protection in the case of direct contact.
Tripping class
AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
CATALOG
NB3LE Residual Current Operated Circuit Breaker with Over-current Protection PDF