HH15/QSA Fuse-switch Disconnector
1.1 Application
Mainly used in the distributing and motor circu which has high short-circuit current, andacted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class with drawable low voltage complete equipment.
They provide safety isolation and protection against overcurrent for any low voltage electrical circuit.
1.2 Standard: IEC/EN 60947-3.
1.3 General characteristic
Full-enclosed structure
Unique rolling insert type contact system.
Related products
NL210 Residual Current Operated Circuit Breaker without Over-current Protection
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
Type B
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
Tripping sensitivity
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;
300mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping (without time-delay).
1.3 Approvals and certificates CE, KEMA
1.4 Add-on devices
AX-5 auxiliary contacts
TC-1 terminal cover
CATALOG
NL210 Residual Current Operated Circuit Breaker without Over-current Protection PDF
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
NB3LE Residual Current Operated Circuit Breaker with Over-current Protection
Rated residual operating current
I∆n = 30 mA: additional protection in the case of direct contact.
Tripping class
AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
CATALOG
NB3LE Residual Current Operated Circuit Breaker with Over-current Protection PDF
NL1 Residual Current Operated Circuit Breaker without Over-current Protection (Magnetic)
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
AC class
Tripping is ensured for slowly increasing sinusoidal AC residual currents.
A class
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
S, G/SI class
Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges.
With the impact of 8/20us surge 3000A, this high immunity
RCCB will still be in stable status.
CATALOG
NL1 Residual Current Operated Circuit Breaker PDF
NXB-63H Miniature Circuit Breaker
Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A,;
Rated voltage: 240V ~ (1P, 1P+N), 415V ~ (2 ~ 4P, 3P+N);
Frequency: 50Hz;
Electromagnetic release type: B, C, D;
Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity: 10000A;
Short-circuit breaking capacity: 7500A;
Rated impulse withstand voltage: 4kV;
CATALOG
NXB-63H Miniature circuit breaker PDF
NXB-125 Moulded Case Circuit Breaker
Rated current: 63A, 80A, 100A, 125A;
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125 Moulded Case Circuit Breaker PDF
HDLRT0 Fuse for Distribution
HDLRT0 Fuse for Distribution
1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A;
2.Application: for protection of power distribution apparatus against over-load and short circuit;
3.Standard: IEC 60269.