H-Class Impregnated Insulated Dry-type Transformer
Application: for power distribution system and industrial enterprises, etc.
Standards: IEC 60076-11
Parameters: Rated Voltage: 10kV.
Rated Capacity: 200-2500kVA.
Features: 1.High security and reliability in operation.
2.Economic and efficient to reduce network loss and working cost.
3.Low noise.
4.Low partial discharge.
5.Operation in moist place with high moisture-proof capability.
6.Customized transformers are available on your requirement.
SKU: POW4536
Categories: Dry-type Transformer (up to 35KV), Electrical Products, Power T&D, Power Transformer
Tags: Dry-type Transformer (up to 35kV), Power T&D, Power Transformer
Related products
NB1L Residual Current Operated Circuit Breaker with Over-current Protection(Magnetic)
1.1 Function
Personnel and fire protection: Cable and line protection against overload and short-circuits.
1.2 Selection
Rated residual operating current
I∆n ≤30 mA: additional protection in the case of direct contact.
I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
Tripping class
AC class
Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
A class
Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
NB1L Residual Current Operated Circuit Breaker with Over-current Protection PDF
NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection (Magnetic)
1.1 Function
Personnel and fire protection: Cable and line protection against overload and short-circuits.
1.2 Selection
Rated residual operating current
I∆n =30 mA: additional protection in the case of direct contact.
Tripping class
A and AC class
A class tripping is ensured for sinusoidal, alternating residual
currents as well as for pulsed DC residual currents, whether they be quickly or slowly increase.
AC class tripping is ensured for sinusoidal, alternating residual currents, whether they be quickly or slowly increase.
Tripping curve
B curve (3 In-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5 In-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
CE/CB/KEMA
1.4 Add-on devices
XF9 auxiliary contacts
S9 shunt release
V9 under voltage release
OVT-1 over voltage release
CATALOG
NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection PDF
NXB-63 Miniature Circuit Breaker
Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A.
CATALOGUE: NXB-63 Miniature circuit breaker PDF
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection
1.1 Selection
Rated residual operating current
I∆n = 30 mA: additional protection in the case of direct contact.
Tripping class
AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big
length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.2 Approvals and certificates
CATALOG
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection PDF
HDLRT0 Fuse for Distribution
HDLRT0 Fuse for Distribution
1.Electric ratings: AC50Hz, AC380V/DC400V, up to 1000A;
2.Application: for protection of power distribution apparatus against over-load and short circuit;
3.Standard: IEC 60269.
NB1-63G Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currentsprotection of circuits against overload currents,switch,isolation,
NB1-63G circuit-breakers are used in domestic installation,as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point consideredshort-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,
Network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrus current.
CATALOG
NB1-63G Miniature Circuit Breaker PDF
NXB-125 Moulded Case Circuit Breaker
Rated current: 63A, 80A, 100A, 125A;
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125 Moulded Case Circuit Breaker PDF