CPS SC20kWUS
The CPS SC20KTL-DO/US-480 grid-tied PV inverter is a tranformerless, three phase product designed for the North America market in compliance with UL and CSA standards. Patented 3-level control algorithm and thermal design provide 97.3% maximum efficiency. CPS SC20KTL-DO/US-480 features small size, light weight and high power density. Multi flexible mounting modes make installation and maintenance easy and quick. The enclosure of the inverter is rated NEMA 3R (IP65) for general purpose outdoor applications. Enhanced DSP control, comprehensive protection functions and advanced thermal design enable a high reliability product with optional warranties up to 20 years.
SKU: COM7445
Categories: Commercial, Electrical Products, Grid-tied PV Inverter, New Energy, Solar Inverters
Tags: commercial, Grid-tied PV Inverter, New Energy
Related products
CPS SC100kWUS
The CPS SC100KT-O/US-480 grid-tied PV inverter is designed for the North America market. The output is designed with a built-in transformer to allow direct connection to low voltage grid. The inverter achieves a 96.8% max efficiency with low loss magnetic materials, advanced MPPT control and variable structure SVPWM controls to minimize the power loss.
The inverter enclosure is rated NEMA 3R for outdoor applications and its compact design minimizes the space required for installation. It also features film-type capacitors, enhanced DSP control, comprehensive protection functions and advance thermal design to make the whole system highly reliable.
eB Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT
systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-20In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
eB Miniature Circuit Breaker PDF
CPS SCE4-7kWUS Series
With advanced transformerless technology, the products reach a 97.5% maximum efficiency, providing competitive, long-term electricy generation benefits.
The enclosures are NEMA 3R rated for general outdoor application. Designed for high reliability and easy installation, CPS SCE series are the ideal choice for residential rooftop applications.
NXB-125G Miniature Circuit Breaker
Rated current: 63, 80, 100(1P, 2P, 3P, 4P), 125(1P, 2P);
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: B, C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icn): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125G Miniature Circuit Breaker PDF
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
CATALOG
NB1-63DC DC Miniature Circuit Breaker PDF
DZ158 Moulded Case Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
DZ158 Moulded Case Circuit Breaker(DC type)
CPS SCA8-12kW Series
This inverter series is suitable for a variety of applications, from large residential to commercial rooftops and utility scale PV systems. With the features of concise design and high reliability of the former generation, these inverters offer an improved performance on the conversion efficiency of reaching up to 98.3%. The internal DC switch further improves the safety and reliability of the products.
NB1-63 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.