330-750kV Power Transformer
Application: For power station, transformer substation, and industrial enterprises, etc..
Standards: IEC 60076-1, IEC 60076-2, IEC 60076-3, IEC 60076-5; ANSI, IEEE, AS, VEIKI, EN, etc.
Parameters: Rated Voltage: up to 750kV
Capacity: up to 1200MVA (Three phases)
Capacity: up to 400MVA (Single phase)
High security and reliability Features: in operation.
Economic and efficient to reduce network loss and operation cost.
High short circuit strength and insulating strength.
Compact design, Low noise and light in weight.
Customized transformers are available on your requirement.
Competitive short delivery time.
SKU: POW8256
Categories: Electrical Products, Oil-immersed Shunt Reactor (up to 500KV), Power T&D, Power Transformer
Tags: Oil-immersed Transformer (up to 750kV), Power T&D, Power Transformer
Related products
NXB-63 Miniature Circuit Breaker
Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A.
CATALOGUE: NXB-63 Miniature circuit breaker PDF
eB Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT
systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-20In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
eB Miniature Circuit Breaker PDF
NBH8 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),
short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
CATALOG
NBH8 Miniature Circuit Breaker PDF
NL1 Residual Current Operated Circuit Breaker without Over-current Protection (Magnetic)
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
AC class
Tripping is ensured for slowly increasing sinusoidal AC residual currents.
A class
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
S, G/SI class
Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges.
With the impact of 8/20us surge 3000A, this high immunity
RCCB will still be in stable status.
CATALOG
NL1 Residual Current Operated Circuit Breaker PDF
NB1-63 Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrushcurrent.
D curve(10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
CATALOG
NB1-63DC DC Miniature Circuit Breaker PDF