166(370~380)AstroSemi_CHSM60M-HC
Power range:370W~380W
Max. system voltage:1500 VDC
Dimention:1765 x 1048 x 35 mm / 69.49 x 41.26 x 1.38 inch
Frame thickness:35 mm / 1.38 inch
Glass thickness:3.2 mm / 0.13 inch
Cable length:Portrait: 350 mm (13.78 inch) Landscape: 1200 mm (47.24 inch)
SKU: SEM62284
Categories: Astro Semi, Electrical Products, New Energy, PV Module
Tags: AstroSemi, New Energy, PV Module, solar panel
Related products
DZ158LE Residual Current Operated Circuit Breaker
1.1 Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.
1.2 Selection
I∆n ≤ 30 mA: additional protection in the case of direct contact.
I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
1.3 Approvals and certificates
CATALOG
DZ158LE Residual Current Operated Circuit Breaker PDF
NB1-63G Miniature Circuit Breaker
1.1 Function
protection of circuits against short-circuit currentsprotection of circuits against overload currents,switch,isolation,
NB1-63G circuit-breakers are used in domestic installation,as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point consideredshort-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,
Network normal voltage.
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrus current.
CATALOG
NB1-63G Miniature Circuit Breaker PDF
DZ158 Moulded Case Circuit Breaker
1.1 Function
protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation.
1.2 Selection
Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG
DZ158 Moulded Case Circuit Breaker(DC type)
NXB-125 Moulded Case Circuit Breaker
Rated current: 63A, 80A, 100A, 125A;
Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P, 2P, 3P, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV;
CATALOG
NXB-125 Moulded Case Circuit Breaker PDF
NB1-63DC DC Miniature Circuit Breaker
1.1 Certificates: CCC,CE,CB,TUV;
1.2 Standard: IEC/EN 60947-2 ,RoHS;
1.3 Rated voltage up to 1000V, Rated current up to 63A;
1.4 Protection of circuits against overload currents;
1.5 Protection of circuits against short-circuit currents;
1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV DC systems.
NXB-63H Miniature Circuit Breaker
Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A,;
Rated voltage: 240V ~ (1P, 1P+N), 415V ~ (2 ~ 4P, 3P+N);
Frequency: 50Hz;
Electromagnetic release type: B, C, D;
Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P;
Mechanical life: 20000 cycles;
Electrical life: 10000 cycles;
Rated short-circuit breaking capacity: 10000A;
Short-circuit breaking capacity: 7500A;
Rated impulse withstand voltage: 4kV;
CATALOG
NXB-63H Miniature circuit breaker PDF
NB1L Residual Current Operated Circuit Breaker with Over-current Protection(Magnetic)
1.1 Function
Personnel and fire protection: Cable and line protection against overload and short-circuits.
1.2 Selection
Rated residual operating current
I∆n ≤30 mA: additional protection in the case of direct contact.
I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
Tripping class
AC class
Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase.
A class
Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Tripping curve
B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems.
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
1.3 Approvals and certificates
Detailed information, please refer to Certificates Table on the last page.
CATALOG