Showing all 6 results

Show sidebar

HXGN15 Air-insulated RMU(Fixed Type)

Application: It is suitable for transformer rooms in power plants, substations and metallurgical and chemical enterprises to distribute power. It has the functions of control, protection and detection etc. Standards: IEC 62271-200 IEC 61439.2-2011 Parameters: 12-24kV 50/60Hz Features: Modular and flexible. Riveted cabinet structure. Intelligent and Compact. Environmental economy. Safe and reliable.

KYN28A-12(Z) Metalclad AC Enclosed Switchgear

Application: In 3.6~12kV power system for control, protection and monitoring. VCBs produced by CHINT or VCBs produced by other manufacturers could be installed in the switchgear panel. Standards:  IEC 62271-200 Parameters: Rated voltage: 3.6-12kV. Rated current: 630-5000A. Rated short-circuit breaking current: 16-50kA. Features:     1.Compact design. 2.Easy operation and installation. 3.Reliable interlock. 4.Less Maintenance.

KYN28A-24(Z) Metalclad AC Enclosed Switchgear

Application: In 3.6~24kV power system for control, protection and monitoring.VCBs produced by CHINT or VCBs produced by other manufacturers could be installed in the switchgear panel. Standards:  IEC 62271-200 Parameters: Rated voltage: 24kV. Rated current: 630-3150A. Rated short-circuit breaking current: 16-31.5kA. Features:      1.KEMA certified. 2.Compact design. 3.Easy operation and installation. 4.Reliable interlock. 5.Less Maintenance.

KYN61-40.5(Z) Metalclad AC Enclosed Switchgear

Application: In the system of 50Hz, 40.5kV, for power distribution, circuit control and protection. Standards:  IEC 62271-200 Parameters: Rated voltage: 40.5kV. Rated current: 630-3150A. Rated short-circuit breaking current: 25-31.5kA. Features:     1.Compact design. 2.Easy operation and installation. 3.Reliable interlock. 4.Less Maintenance.

NG7 C-GIS MV Switchgear

Application: ring network power supply or dual radiant power supply for 12~40.5kV power supply line. Standards: IEC62271-200 IEC62271-10 IEC62271-1 Parameters: 12~40.5kV Features: Adapt to operation environment High level of protection Compact structure Flexible expansion Maintenance free Operation reliability

XGN15 Air-insulated RMU(Fixed Type)

Application: It is suitable for transformer rooms in power plants, substations and metallurgical and chemical enterprises to distribute power. It has the functions of control, protection and detection etc. Standards: IEC 62271-200 IEC 61439.2-2011 Parameters: 12-24kV 50/60Hz Features: Modular and flexible. Riveted cabinet structure. Intelligent and Compact. Environmental economy. Safe and reliable.