Showing all 12 results

Show sidebar

DZ158 Moulded Case Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG DZ158 Moulded Case Circuit Breaker(DC type)

eB Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrushcurrent. D curve(10-20In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG eB Miniature Circuit Breaker PDF

NB1-63 Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems. 1.2 Selection Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT  systems. C curve (5-10In) protection for resistive and inductive loads with low inrushcurrent. D curve(10-14In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page.

NB1-63DC DC Miniature Circuit Breaker

1.1 Certificates: CCC,CE,CB,TUV; 1.2 Standard: IEC/EN 60947-2 ,RoHS; 1.3 Rated voltage up to 1000V, Rated current up to 63A; 1.4 Protection of circuits against overload currents; 1.5 Protection of circuits against short-circuit currents; 1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV   DC systems.

NB1-63DC DC Miniature Circuit Breaker

1.1 Certificates: CCC,CE,CB,TUV; 1.2 Standard: IEC/EN 60947-2 ,RoHS; 1.3 Rated voltage up to 1000V, Rated current up to 63A; 1.4 Protection of circuits against overload currents; 1.5 Protection of circuits against short-circuit currents; 1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV   DC systems. CATALOG NB1-63DC DC Miniature Circuit Breaker PDF

NB7 Miniature Circuit Breaker

The NB7 series miniature circuit breaker is applicable to the circuit with an alternating  current of 50Hz/60Hz, rated voltage of 240/415V, and rated current up to 63A for overload protection and short circuit protection, and also for not-frequent operational transformation in the circuit under normal condition. This product can be applied to various places such as industrial, commercial, and tall buildings, and residential houses. The product meets the standards of IEC60898-1. NB7 Miniature Circuit Breaker PDF  

NBH8 Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC), short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates CATALOG NBH8 Miniature Circuit Breaker PDF

NXB-125 Moulded Case Circuit Breaker

Rated current: 63A, 80A, 100A, 125A; Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icu): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125 Moulded Case Circuit Breaker PDF

NXB-125G Miniature Circuit Breaker

Rated current: 63, 80, 100(1P, 2P, 3P, 4P), 125(1P, 2P); Rated voltage: 240V ~ (1P), 415V ~ (2P, 3P, 4P); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 2P, 3P, 4P; Mechanical life: 20000 cycles; Electrical life: 6000 cycles (In≤100A); 4000 cycles (In>100A); Rated short-circuit breaking capacity(Icn): 10000A; Short-circuit breaking capacity(Ics): 7500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-125G Miniature Circuit Breaker PDF

NXB-40 Miniature Circuit Breaker

Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A; Rated voltage: 240V; Frequency: 50Hz; Electromagnetic release type: C, D; Number of poles: 1P+N; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity(Icu): 4500A; Short-circuit breaking capacity(Ics): 4500A; Rated impulse withstand voltage(Uimp): 4kV; CATALOG NXB-40 Miniature Circuit Breaker PDF  

NXB-63 Miniature Circuit Breaker

Overload protection, short circuit protection and isolation. It is widely used in building power distribution, industrial power distribution, as well as control and protection for a variety of equipment with operating current not exceeding 125A. CATALOGUE: NXB-63 Miniature circuit breaker PDF

NXB-63H Miniature Circuit Breaker

Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A,; Rated voltage: 240V ~ (1P, 1P+N), 415V ~ (2 ~ 4P, 3P+N); Frequency: 50Hz; Electromagnetic release type: B, C, D; Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P; Mechanical life: 20000 cycles; Electrical life: 10000 cycles; Rated short-circuit breaking capacity: 10000A; Short-circuit breaking capacity: 7500A; Rated impulse withstand voltage: 4kV; CATALOG NXB-63H Miniature circuit breaker PDF