DDSU666 Single Phase DIN-Rail Meter

Reliable Choice ◎ LCD Display ◎ Bi-Direction Measurement ◎ DIN-Rail installation CATALOG DDSU666 PDF

DTSU666 Three Phase DIN-Rail Meter

Reliable Choice ◎ LCD Display ◎ Bi-Direction Measurement ◎ DIN-Rail installation CATALOG DTSU666 PDF

DZ158 Moulded Case Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG DZ158 Moulded Case Circuit Breaker(DC type)

DZ158LE Residual Current Operated Circuit Breaker

1.1 Function Personnel and fire protection Cable and line protection against overload and short-circuits. 1.2 Selection I∆n ≤ 30 mA: additional protection in the case of direct contact. I∆n ≤300 mA: preventative fire protection in the case of ground fault currents. AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. 1.3 Approvals and certificates CATALOG DZ158LE Residual Current Operated Circuit Breaker PDF

eB Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrushcurrent. D curve(10-20In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG eB Miniature Circuit Breaker PDF

NB1-63 Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. NB1 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems. 1.2 Selection Technical data of the network at the point considered:short-circuit current at the circuit-breaker installation point,  which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT  systems. C curve (5-10In) protection for resistive and inductive loads with low inrushcurrent. D curve(10-14In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps). 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page.

NB1-63DC DC Miniature Circuit Breaker

1.1 Certificates: CCC,CE,CB,TUV; 1.2 Standard: IEC/EN 60947-2 ,RoHS; 1.3 Rated voltage up to 1000V, Rated current up to 63A; 1.4 Protection of circuits against overload currents; 1.5 Protection of circuits against short-circuit currents; 1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV   DC systems.

NB1-63DC DC Miniature Circuit Breaker

1.1 Certificates: CCC,CE,CB,TUV; 1.2 Standard: IEC/EN 60947-2 ,RoHS; 1.3 Rated voltage up to 1000V, Rated current up to 63A; 1.4 Protection of circuits against overload currents; 1.5 Protection of circuits against short-circuit currents; 1.6 NB1-63 DC circuit-breakers are used incommunication systems and PV   DC systems. CATALOG NB1-63DC DC Miniature Circuit Breaker PDF

NB1L Residual Current Operated Circuit Breaker with Over-current Protection(Magnetic)

1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. 1.2 Selection Rated residual operating current I∆n ≤30 mA: additional protection in the case of direct contact. I∆n ≤300 mA: preventative fire protection in the case of ground fault currents. Tripping class AC class Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. A class Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against  overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG NB1L Residual Current Operated Circuit Breaker with Over-current Protection PDF  

NB2LE Residual Current Operated Circuit Breaker

The NB2LE residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, rated current up to 25A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be protected. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses. CATALOG NB2LE Residual Current Operated Circuit Breaker PDF

NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection (Magnetic)

1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. 1.2 Selection Rated residual operating current I∆n =30 mA: additional protection in the case of direct contact. Tripping class A and AC class A class tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly or slowly increase. AC class tripping is ensured for sinusoidal, alternating residual currents, whether they be quickly or slowly increase. Tripping curve B curve (3 In-5 In) protection and control of the circuits against  overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5  In-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates CE/CB/KEMA 1.4 Add-on devices XF9 auxiliary contacts S9 shunt release V9 under voltage release OVT-1 over voltage release CATALOG NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection PDF

NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection

1.1 Selection Rated residual operating current I∆n = 30 mA: additional protection in the case of direct contact. Tripping class AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.2 Approvals and certificates CATALOG NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection PDF

NB7 Miniature Circuit Breaker

The NB7 series miniature circuit breaker is applicable to the circuit with an alternating  current of 50Hz/60Hz, rated voltage of 240/415V, and rated current up to 63A for overload protection and short circuit protection, and also for not-frequent operational transformation in the circuit under normal condition. This product can be applied to various places such as industrial, commercial, and tall buildings, and residential houses. The product meets the standards of IEC60898-1. NB7 Miniature Circuit Breaker PDF  

NBH8 Miniature Circuit Breaker

1.1 Function protection of circuits against short-circuit currents,protection of circuits against overload currents,switch,isolation. 1.2 Selection Technical data of the network at the point considered:the earthing systems (TNS, TNC), short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,network normal voltage. Tripping curves: B curve (3-5In) protection for people and big length cables in TN and IT systems. C curve (5-10In) protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates CATALOG NBH8 Miniature Circuit Breaker PDF

NBH8LE Residual Current Operated Circuit Breaker with over-current protection (Electronic)

1.1 Function Personnel and fire protection Cable and line protection against overload and short-circuits. 1.2 Selection I∆n = 10mA, 30mA: additional protection in the case of direct contact. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. CATALOG NBH8LE Residual Current Operated Circuit Breaker with over-current protection PDF

NCH8 Modular AC Contactor 20~63A

1.1 Electric ratings: up to 20A, 25A,  40A, 63A, 230V, 400V   AC50/60Hz; 1.2 Utilization category: AC-1, AC-7a, AC-7b; 1.3 Standard: IEC/EN 61095 CATALOG NCH8 Modular AC Contactor PDF

NCH8-M modular contactor with manual operation 16-63A

NCH8-□M series Manual Modular AC contactor (here in after referred as contactor) is mainly used in power systems with AC 50Hz/60Hz, rated operating voltage up to 400V and rated operating current up to 63A. It is used as remote or manual switch for circuit control under AC-7a and AC-7b (non-inductive load or low-inductive load/resistance furnace,domestic appliance and low-inductive load of similar applications) application category. The contactor shall not be used for breaking short-circuit current, therefore it should be used with a proper short-circuit protection device. CATALOG EN NCH8-□M PDF

ND9 Indicator Light

ND9 Indicator Light 1. General 1.1 Electric ratings: 230V, AC50/60Hz; 1.2 Rated insulation voltage Ui: 500V; 1.3 Protection grade: IP20 1.4 Rated operational current: ≤20mA 1.5 Life: LED≥30000h; 1.6 Standard: IEC/EN 60947-5-1 2. Operating Conditions 2.1 Ambient temperature: -5℃~+40℃, average temperature in 24 hours not exceed +35℃; 2.2 Altitude: ≤ 2000m; 2.3 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken to occurrence of dews; 2.4 Mounting category: Ⅱ, Ⅲ; 2.5 Pollution grade: Ⅱ; 2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5° 3. Wirng 2 Cross section area of the conductor is 1.0mm , and tightening torque should be 0.8N•m CATALOG ND9 Indicator Light PDF

NH2 Switch Disconnector

1. 1 In the open position, It complies with the requirements of the isolating function. 1.2 It is designed match DZ series MCBs/RCBOs. CATALOG NH2 Switch Disconnector PDF

NH4 Switch Disconnector

1.1 In the open position, It complies with therequirements of the isolating function. 1.2 It is designed match NB series MCBs/RCBOs. CATALOG NH4 Switch Disconnector PDF

NL1 Residual Current Operated Circuit Breaker without Over-current Protection (Magnetic)

1.1 Function Control electric circuits. Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers are used in housing, tertiary sector and industry. 1.2 Selection Detectable wave form AC class Tripping is ensured for slowly increasing sinusoidal AC residual currents. A class Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly. S, G/SI class Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status. CATALOG NL1 Residual Current Operated Circuit Breaker PDF

NL210 Residual Current Operated Circuit Breaker without Over-current Protection

1.1 Function Control electric circuits. Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers are used in housing, tertiary sector and industry. 1.2 Selection Detectable wave form Type B Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly. Tripping sensitivity 30mA - additional protection against direct contact. 100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts; 300mA - protection against indirect contacts, as well as fire hazard. Tripping time Instantaneous It ensures instantaneous tripping (without time-delay). 1.3 Approvals and certificates CE, KEMA 1.4 Add-on devices AX-5 auxiliary contacts TC-1 terminal cover CATALOG NL210 Residual Current Operated Circuit Breaker without Over-current Protection PDF  

NM1 Moulded Case Circuit Breaker

1.1 Certificates: KEMA, UKrSEPRO, EAC, RCC, EK; 1.2 Electric ratings: AC 690V,50/60HZ, 10~1250A; 1.3 Mounting mode: Vertical and horizontal; 1.4 Standard: IEC/EN60947-2.