Show sidebar

ND16 Indicator Light

1. General Degree of protection: IP65,IP40,IP20(Buzzer); Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅲ 2.6 Tightening torque is 0.8~1.2N·m for the cable terminals, and 1.5~1.8N·m for the fixing nut. Cross section of the cable connection is 0.5~2.5mm2. CATALOG ND16 Indicator Light PDF

NP2 Series Pushbutton

1. General Electric ratings: AC50/60Hz, AC380V/DC220V; Degree of protection: IP40; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃,the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature,special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅱ 2.6 Tightening torque is 0.8~1.2N·m for the cable terminals. Cross section of the cable connection is 0.5~2.5mm2, and 8mm conductor length is needed.

NP3 Series Pushbutton

1. General Electric ratings: AC50/60Hz, AC380V/DC220V; Degree of protection: IP65; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relatice humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅱ

NP6 Series Pushbutton

1. General Electric ratings: AC50/60Hz, AC220V/DC220V; Degree of protection: IP40; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution degree: 3 2.5 Overvoltage category: Ⅱ CATALOG NP6 Series Pushbutton PDF

NPH1 Pushbutton Box

1. General Electric ratings: AC50/60Hz, AC415V/DC250V; Degree of protection: IP65; Standard: IEC/EN60947-5-1 2. Operating conditions 2.1 Ambient temperature is -5℃~+40℃, the average temperature during 24 hours couldn't exceed +35℃. 2.2 Altitude: ≤2000m. 2.3 Atmosphere condition: Relative humidity of the atmosphere couldn't exceed 50% when the highest temperature is +40℃; much higher relative humidity is allowable under the condition of lower temperature, for example, when the temperature reaches +20℃, the relative humidity is up to 90%. As for dews, which contingently appear due to change of temperature, special steps should be taken. 2.4 Pollution grade: 3 2.5 Installation category: Ⅱ 2.6 Tightening torque is 0.8~1.2N·m for the cable terminals. Cross section of the cable connection is 0.5~2.5mm2, and 8mm conductor length is needed.