DZ158LE Residual Current Operated Circuit Breaker

1.1 Function Personnel and fire protection Cable and line protection against overload and short-circuits. 1.2 Selection I∆n ≤ 30 mA: additional protection in the case of direct contact. I∆n ≤300 mA: preventative fire protection in the case of ground fault currents. AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. 1.3 Approvals and certificates CATALOG DZ158LE Residual Current Operated Circuit Breaker PDF

NB1L Residual Current Operated Circuit Breaker with Over-current Protection(Magnetic)

1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. 1.2 Selection Rated residual operating current I∆n ≤30 mA: additional protection in the case of direct contact. I∆n ≤300 mA: preventative fire protection in the case of ground fault currents. Tripping class AC class Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. A class Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against  overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates Detailed information, please refer to Certificates Table on the last page. CATALOG NB1L Residual Current Operated Circuit Breaker with Over-current Protection PDF  

NB2LE Residual Current Operated Circuit Breaker

The NB2LE residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, rated current up to 25A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be protected. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses. CATALOG NB2LE Residual Current Operated Circuit Breaker PDF

NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection (Magnetic)

1.1 Function Personnel and fire protection: Cable and line protection against overload and short-circuits. 1.2 Selection Rated residual operating current I∆n =30 mA: additional protection in the case of direct contact. Tripping class A and AC class A class tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly or slowly increase. AC class tripping is ensured for sinusoidal, alternating residual currents, whether they be quickly or slowly increase. Tripping curve B curve (3 In-5 In) protection and control of the circuits against  overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5  In-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.3 Approvals and certificates CE/CB/KEMA 1.4 Add-on devices XF9 auxiliary contacts S9 shunt release V9 under voltage release OVT-1 over voltage release CATALOG NB310L(3PN) Residual Current Operated Circuit Breaker with over-current protection PDF

NB3LE Residual Current Operated Circuit Breaker with Over-current Protection

Rated residual operating current I∆n = 30 mA: additional protection in the case of direct contact. Tripping class AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. CATALOG NB3LE Residual Current Operated Circuit Breaker with Over-current Protection PDF

NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection

1.1 Selection Rated residual operating current I∆n = 30 mA: additional protection in the case of direct contact. Tripping class AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase. Tripping curve B curve (3-5 In) protection and control of the circuits against overloads and short-circuits; protection for people and big length cables in TN and IT systems. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. 1.2 Approvals and certificates CATALOG NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection PDF

NBH8LE Residual Current Operated Circuit Breaker with over-current protection (Electronic)

1.1 Function Personnel and fire protection Cable and line protection against overload and short-circuits. 1.2 Selection I∆n = 10mA, 30mA: additional protection in the case of direct contact. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. AC class – Tripping is ensured for sinusoidal,alternating currents, whether they be quickly applied or slowly increase. CATALOG NBH8LE Residual Current Operated Circuit Breaker with over-current protection PDF