Showing all 18 results

Show sidebar

CJ19 Contactor for Capacitor Switching

1.1 Electric ratings: AC50/60Hz, up to 690V; 1.2 Standard: IEC/EN 60947-4-1 CATALOG CJ19 Contactor for Capacitor Switching PDF

NC1 AC Contactor, 9~95A

1.1 Certificates: CE, KEMA, VDE, EK, UKrSEPRO, EAC,  RCC, UL; 1.2 Electric ratings: AC50/60Hz, 690V, up to 95A; 1.3 Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; Frequent start-up and control of AC contactor; 1.4 Utilization category: AC-3, AC-4; 1.5 Altitude: ≤2000m; 1.6 Ambient temperature: -5℃~+40℃; 1.7 Mounting category: Ⅲ 1.8 Mounting conditions: inclination between the mounting plane and the vertical plane should not                            exceed ±5° 1.9 Standard: IEC/EN 60947-4-1

NC2 AC Contactor, 115~800A

1.1 Certificates: NC2-115~800 CE, VDE, UKrSEPRO, EAC, RCC, UL; 1.2 Electric ratings: AC50/60Hz, up to 690V, up to 800A; 1.3 Application: remote making & breaking circuits  protect circuit from overload when assembling with thermal over-load relay; 1.4 Ambient temperature: -5℃~+40℃; 1.5 Altitude: ≤2000m; 1.6 Mounting category: Ⅲ 1.7 Mounting conditions: inclination between the mounting plane and the vertical plane not exceed ±5° 1.8 Standard: IEC/EN 60947-4-1

NC6 AC Contactor, 6~9A

1.1 Certificates: CE, VDE, UKrSEPRO, EAC, UL; 1.2 Electric ratings: AC50/60Hz, up to 690V, up to 9A; 1.3 Application: remotely makes and breaks circuit, protect circuit from overload assembling with proper thermal relay; 1.4 Utilization category: AC-1, AC-3, AC-4; 1.5 Ambient temperature: -5℃~+40℃; 1.6 Altitude: ≤2000m; 1.7 Mounting category:  Ⅲ .1.8 Mounting conditions: inclination between mounting plane and vertical plane not exceed ±30° 1.9 Standard: IEC/EN 60947-4-1

NC7 AC Contactor,09~620A

The NC7 series AC contactor (hereinafter referred to as “contactor”) is mainly used in the  circuit with an alternating current of 50Hz (or 60Hz), rated operational voltage up to 690V, and  rated operational current up to 620A under the usage category of AC-3/400V; this contactor is mainly used for remotely closing and breaking circuits, and can be combined with an appropriate  thermal overload relay to form a electromagnetic starter so as to protect the circuits likely to  be overloaded in operation; the contactor is well suited for frequently starting and controlling  AC motors. Standard: IEC60947-4-1

NC8 AC Contactor,06~500A

NC8 series AC contactor is applied to circuits with AC current frequency of 50 Hz or 60 Hz, rated  operationalvoltage up to 690 V and rated operational current up to 500 A. It is used for remote  making & breaking circuits, and can also be used with proper thermal overload relay together as an  electromagnetic starter to protect circuits from overload. Standard: IEC/EN 60947-4-1.

NC9 AC Contactor

1.1 Certificates: CE, UKrSEPRO; 1.2 Electrical ratings: AC50Hz, up to 1,140V, up to 1,000A; 1.3 Application: remotely makes and breaks circuit,  combined with thermal over-load relay or some protective devices to be vacuum starter; 1.4 Ambient temperature: -5℃~+40℃; 1.5 Altitude: ≤2,000m; 1.6 Mounting category: Ⅲ 1.7 Mounting conditions:  the inclination between mounting and vertical plane not exceed  ±15° 1.8 Standard: IEC/EN 60947-4-1

NCK3 Definite Purpose Contactor 20~90A

1.1 Certificates: UL; 1.2 Application: HVACR; 1.3 Utilization category: AC-1, AC-8a; 1.4 Rated insulation voltage: 630V; 1.5 Standard: UL508 CATALOG NCK3 Definite Purpose Contactor 20~90A PDF

NCK5 Definite Purpose Contactor 20~40A

1.1 Product certification: UL, CSA 1.2 Application: HVACR 1.3 Usage category: AC-1, AC-8a 1.4 Rated insulation voltage Ui: 630V 1.5 Applicable standard: UL/CSA 60947-4-1 CATALOG NCK5 Definite Purpose Contactor 20~40A PDF

NKB1 Control & Protective Switching Device

NKB1 series control & protective switching device (CPS) is mainly applied to circuit with AC current frequency of 50 Hz or 60Hz, rated operational voltage up to 690V, rated operational current from 1A to 125A, controller setting current from 0.4A to 125A, control motor power from 0.12kW to 55kW. It is capable of making, carrying and breaking currents under normal conditions, including specified operating overload conditions and of making, carrying for a specified time and breaking currents under specified abnormal conditions such as those of short-circuits. NBK1 series CPS is applied to power distribution and motor protection & control of various occasions or systems, e.g. infrastructure, buildings, communications, etc. Standard: IEC60947-6-2 Multiple function equipment-Control and protective switching devices (or equipment) (CPS). CATALOG NKB1 Control & Protective Switching Device PDF

NQ2 Direct On-line Starter

1.1 NQ2 series electromagnetic starter ( "starter" for short hereinafter) applies mainly to circuit     with AC current of 50Hz (or 60Hz), rated operational voltage of 660V  and rated controlled         power up to 33kW (current up to 68A)for using to control the direct start and halt of the           electromotor to protect the motor from overload and phase failure. 1.2 The starter conforms to standards IEC/EN60947-4-1 CATALOG NQ2 Direct On-line Starter PDF

NQ3 Series DOL Electromagnetic Starter

1.1 NQ3 series electromagnetic starter ( "starter" for short hereinafter) applies mainly to circuit with AC current of 50Hz (or 60Hz), rated operational voltage of 660V and rated controlled power up to 11kW (current up to 22A) for using to control the direct start and halt of the electromotor to protect the motor from overload and phase failure. 1.2 The starter conforms to standards IEC/EN60947-4-1 CATALOG NQ3 Series DOL Electromagnetic Starter PDF

NR2 Thermal Overload Relay

1.1 Certificates: CE, KEMA, UkrSEPRO, EAC, RCC, UL; 1.2 Electric ratings: AC 50/60Hz, 690V, 0.1A~630A; 1.3 Tripping class: 10A; 1.4 Mounting version: a. Plug-in: Available for NR2-11.5, 25, 36, 93, 150; b. Independent: Available for NR2-200, 630; 1.5 Standard: IEC/EN 60947-4-1 CATALOG NR2 Thermal Overload Relay PDF

NR8 Thermal Overload Relay

Nr8 series thermal overload relay (hereinafter referred to as thermal relay) is used to provide      overload and phase failure protection for AC motors with a frequency of AC 50Hz/60Hz, a voltage of  up to 690V and a current of 0.1A~38A that operate continuously or intermittently. The thermal relay also has temperature compensation, operation indication, automatic and manual    reset and stop functions and stable and reliable performances. Standard: IEC 60947-4-1. Plug-in mounting is used between the thernal relay  and the contactor.

NRE8 Electronic Overload Relay

1.1 Certificates: CE, UKrSEPRO, UL; 1.2 Electrical ratings: AC50/60Hz, 690V; 1.3 Standards: IEC/EN 60947-4-1, UL508 CATALOG NR8 Thermal Overload Relay PDF

NS2 Motor Starter

1.1 Certificates: SEMKO, CE, UkrSEPRO, EAC, RCC, UL; 1.2 Electric ratings: AC690V, 25A, 80A; 1.3 Standard: IEC/EN 60947-2, IEC60947-4-1 CATALOG NS2 Motor Starter PDF

NXC AC Contactor

The new NXC AC contactors feature a novel appearance and a compact structure. They are mainly used for frequent starts and control of AC motors as well as remote circuit making /breaking. They can also be combined with appropriate thermal overload relays to form electromagnetic starters. Compliant standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1.

NXR Thermal Overload Relay

NXR thermal overload relays (hereinafter abbreviated as thermal relays) are suitable for overload and phase loss protection for uninterrupted or intermittent AC motors with AC frequency of 50 Hz/60 Hz, a voltage up to 690 V, and a current of (0.1-630)A. The thermal relays also provide temperature compensation, action indication, automatic and manual reset, stop, and testing functions. The products are characterized by stable and reliable performance. The thermal relays can be plugged into contactors or installed indepe-ndently. Compliant standards: IEC/EN 60947-4-1, IEC/EN 60947-5-1.